Controller (MCS-6E) Features and Functions:
• Pre-programmed to switch on two sets of outputs depending how many times the single push button is pressed
• 6 x 10Amp solid state relay outputs
• Collective total current rating is 24 Amp
• Each output can be current protected set at 5 or 10 Amps - no external fuses required
• Side light input for illumination control - positive
• Input Ignition input for wake-up control - positive
• Input Low battery 'auto shut down' feature sets in when voltage level falls below 11.5 volts for more than 30 seconds
• Automatic 'sleep mode' sets in after periods of inactivity or low voltage
• 12 and 24 volt operation
Single Cyclic Switch Features and Functions:
• Momentary 3-way cyclic switch with dual colour (blue and red) LED illumination that changes colour with each
press to display the selected mode of operation or is unlit when off
• 22mm front bezel micro switch
• Brushed steel anti-vandal switch
• Dual colour LED - blue/red
• Ingress protected to IP65
• 3 year manufacturers warranty
INPUT RELATIONSHIP WITH OUTPUTS
INPUT
| SWITCH
| OPERATES
|
IP1
| Not used
| No action
|
IP2
| Not used
| No action
|
IP3
| Not used
| No action
|
IP4
| Not used
| No action
|
IP5
| Not used
| No Action
|
IP6
| 1st Press 2nd Press 3rd Press
| Off OP1 & OP4 OP2 & OP3
|
Note: This device is specifically pre-programmed to operate as described above.
OUTPUT FUNCTIONS
INPUT
| FUNCTION
| EXAMPLE BLUE LIGHT USE
| EXAMPLE AMBER LIGHT USE
|
OP1
| 1st Group of Devices
| 999 Group
| Towing Group
|
OP2
| 1st and 2nd Group of Devices
| At Scene Group
| Roadside Working Group
|
OP3
| 2nd Group of Devices
| At Scene Group
| Roadside Working Group
|
OP4
| 1st Group of Devices
| 999 Group
| Towing Group
|
OP5
| Blue LED in Switch
| Not available to use
| Not available to use
|
OP6
| Red LED in Switch
| Not available to use
| Not available to use
|
Note: Each output can drive any appropriate device so long as each is rated under 10 Amp with a collective total of 24 Amp.