MCS-6E Features and Functions:
• Pre-programmed to switch on two sets of outputs depending how many times the single push button is pressed
• 6 x 10Amp solid state relay outputs
• Collective total current rating is 24 Amp
• Each output can be current protected set at 5 or 10 Amps - no external fuses required
• Side light input for illumination control - positive
• Input Ignition input for wake-up control - positive
• Input Low battery ‘auto shut down’ feature sets in when voltage level falls below 11.5 volts for more than 30 seconds
• Automatic ‘sleep mode’ sets in after periods of inactivity or low voltage
• 12 and 24 volt operation
• 3 year manufacturers warranty
Input Relationship with Outputs
INPUT
| SWITCH SENSE
| OPERATES
|
IP1
| Positive
| OP1
|
IP2
| Positive
| OP2
|
IP3
| Positive
| OP3
|
IP4
| Positive
| OP4
|
IP5
| Negative
| OP5
|
IP6
| Negative
| OP6
|
Output Functions
OUTPUT
| FUNCTION
| EXAMPLE BLUE LIGHT USE
| EXAMPLE AMBER LIGHT USE
|
OP1
| 1st Individual Device
| Front Blues
| Towing Lights On
|
OP2
| 2nd Individual Device
| Rear Blues
| Roadside Working Lights On
|
OP3
| 3rd Individual Device
| Rear Reds
| Rear Work Lamps On
|
OP4
| 4th Individual Device
| Off-Side Alley
| Front Work Lamps On
|
OP5
| 5th Individual Device
| Near-Side Alley
| Winch Active
|
OP6
| 6th Individual Device
| Siren Arm
| Interior Lights On
|
Note: Each output can drive any appropriate device so long as each is rated under 10 Amp with a collective total of 24 Amp.